
Add to Cart
Clean Room Entrance Cargo Air Shower Purifying Equipment Air Shower
Air showers are enclosures specially designed and designed for the removal of particles from people or materials, prior to their access or exit from certain clean areas. They allow the cleaning of the particles that remain deposited in the user’s clothing or materials and are used mainly in the income to clean areas with high classification requirements, such as sterile areas, and exits of areas in containment.
They are cabins that are specially prepared to remove dust particles and polluting products that may be deposited in personnel’s work materials or clothing at the entrance or exit of clean or containment areas.
Air Shower Features:
• 240V/220V/380V standard - specify what power you need when ordering
• Removes surface-deposited particles from personnel prior to entering the cleanroom
• Self-contained, turnkey chambers are preassembled at the factory and shipped in two sections (top and bottom) for fast installation
• HEPA-filtered air (rated 99.99% efficient at 0.3 microns) washes over personnel to dislodge loose particles that accumulate on garments
• Electromagnetic interlock system prevents the doors from opening before the air shower cycle is completed, protecting the cleanroom from cross-contamination
• Door locks automatically release in the event of a power outage or if one of the Emergency Exit buttons are depressed
• Shower time and door interlock duration can be programmed using the touchscreen control panel
• Air nozzles can be adjusted to redirect streams of air
• Energy-efficient LED lighting includes motion-activation
Show less
Person Air Shower Specifications:
Suitable Number | 1-2 person | 2person | 4-6person |
Model | AL-AS1300/P1 | AL-AS1300/S1 | AL-AS1300/P2 |
External Size (W×D×H)mm | 1300×1000×2180 | 1300×1500×2180 | 1300×3000×2180 |
Internal Work Zone (W×D×H)mm | 800×800×1960 | 800×1430×1960 | 800×2930×1960 |
Noise Level(dB) | <62 | <62 | <62 |
Stainless Steel Nozzle | 16PCS | 24PCS | 48PCS |
Wind Speed | ≥25m/s | ≥25m/s | ≥25m/s |
Prefilter | Washable type, Aluminum frame, G1-G4 | ||
HEPA Filter | Mini-pleated Type, Aluminum frame, 99.99% 0.3µm | ||
Fluorescent Lamp | 20W×1 | 20W×2 | 20W×2 |
Power Supply | 380V/50Hz | 380V/50Hz | 380V/50Hz |
Total Power | 2.3KW | 4.7KW | 4.7KW |
Cargo Air Shower Specifications:
Model | AL-GS1800/S1 | AL-GS2000/S1 | AL-AS2200/S1 |
External Size (W×D×H)mm | 1800×1500×2180 | 2000×1500×2180 | 2200×1500×2180 |
Internal Work Zone (W×D×H)mm | 1300×1430×1980 | 1500×1430×1980 | 1700×1430×1980 |
Noise Level(dB) | <62 | <62 | <62 |
Stainless Steel Nozzle | 16PCS | 24PCS | 48PCS |
Wind Speed | ≥25m/s | ≥25m/s | ≥25m/s |
Prefilter | Washable type, Aluminum frame, G1-G4 | ||
HEPA Filter | Mini-pleated Type, Aluminum frame, 99.99% 0.3µm | ||
Fluorescent Lamp | 20W×1 | 20W×2 | 20W×2 |
Power Supply | 380V/50Hz | 380V/50Hz | 380V/50Hz |
Total Power | 2.3KW | 4.7KW | 4.7KW |
Enter the Cleanroom without Dust!
Each unit is a fully equipped, protected passageway that allows large numbers of personnel to pass into controlled areas without sacrificing convenience or cleanliness.
Air Showers and Tunnels supply concentrated Class 100, clean air flows to lift off contamination while an individual stands in, or walks through, a specially constructed air chamber. Whenever an automatic floor switch inside the unit is activated, pressurized air streams from adjustable nozzles at a velocity between 6,000 and 8,000 feet per minute (30 m/s and 41 m/s), a force that ensures efficient scrubbing action necessary to remove particulate matter. (Air showers in units without floors are activated by motion sensors.)
Nozzles are arranged on walls and ceilings in a uniform pattern to ensure effective distribution of filtered air; the lowest nozzle is positioned 19" (483 mm) off the floor. The closed-loop circulation design directs contaminated air downward through grills and hollow walls of the Air Shower and back to the filter, which removes 99.97% of all particles as small as 0.3 microns.
Interlocking doors prevent unnecessary contamination inflow and thereby prevent cross-contamination of the cleanroom and the Air Shower or Tunnel. They automatically release in the event of a power failure to ensure operator safety. Fluorescent lighting, built into the ceiling to allow unimpeded air circulation, ensures full visibility no matter what size or configuration you select. In addition, an emergency stop button on each Air Shower/Tunnel sounds an alarm and releases the door lock for exiting.