
Add to Cart
CE Certified Horizontal Laminar flow Work bench Hood with 99.999% High Efficiency HEPA filter
Vertical Laminar Flow Hoods- Economical Clean Bench
Economical laminar flow cabinet with clean, simple, low-maintenance design is a work bench with class 100 / ISO5 environment can be used in assembly, testing and inspection procedures that require a continuous flow of ultra clean air.
These bench-top polypropylene vertical laminar flow hoods feature 99.99% efficient HEPA or 99.999% efficient ULPA fan / filter modules that remove particulate airborne contamination.
Application:
It can be widely used in medicine, bio-pharmaceutical, food, optics, microelectronics, sterile laboratory, lant tissue culture etc.
Horizontal CLEAN BENCH Specifications:
Model | AL-LC1200 | AL-LC1500 | AL-LC1800 |
External Size (WxLxH)mm | 1200x780x1580 | 1500x780x1580 | 1800x780x1580 |
Internal Size (WxLxH)mm | 1100x600x650 | 1400x600x650 | 1700x600x650 |
Air Flow (m³/h) | 800 ~ 1200 | 1000 ~ 1500 | 1500 ~ 2000 |
Wind Velocity | 0.25 ~ 0.45 m/s | ||
Purification rank | 100 rank (ISO14644-1 standard) |
Vertical CLEAN BENCH Specifications:
Model | AL-VC1200 | AL-VC1500 | AL-VC1800 |
External Size (WxLxH)mm | 1200x700x1800 | 1500x700x1800 | 1800x700x1800 |
Internal Size (WxLxH)mm | 1100x650x600 | 1400x650x600 | 1700x650x600 |
Air Flow (m³/h) | 800 ~ 1200 | 1000 ~ 1500 | 1500 ~ 2000 |
Wind Velocity | 0.25 ~ 0.45 m/s | ||
Purification rank | 100 rank (ISO14644-1 standard) |
What does a clean bench do?
The clean bench is recommended for work with non-hazardous materials where clean, particle-free air is necessary to avoid contamination. The clean bench ensures that the work surface is constantly flooded with HEPA-filtered air in a laminar flow. Unlike a biological safety cabinet, the clean bench protects the work on the work surface, but not personnel or the surrounding environment from aerosols created on the work surface. The HEPA air filter can trap 99.999% of particles with a diameter greater than and less than 0.3 micron.
Why Laminar flow?
Clean benches are equipped with either vertical or horizontal laminar flow. Both of these configurations provide a unidirectional velocity along parallel flow lines. Simply, all of the air inside the confines of the bench flows in a single direction without backwash, typically an an area of turbulent airflow created by obstructions, equipment, or movement within the clean bench enclosure. Proper enclosure design helps prevent backwash and ensures that the vertical or horizontal laminar air flow continues to protect work on the surface of the clean bench.